EonStor DS S48 Series Hardware Manual
XML format (please refer to EonStor DS SANWatch User Manual section on
Replacing System Configurations). If you choose to manually set all settings,
you may skip this step.
Step 5
. Power off the system (refer to section
), disconnect all
cables and remove all modules from the existing enclosure.
Step 6
. Remove the existing enclosure from your rack and install the new enclosure
onto the rack.
Step 7
. Reinsert all modules removed into the new enclosure and reconnect all
cables
Step 8
. Power on the system and confirm module statuses by checking all status
LEDs (please refer to section
and
).
Step 9
. Once booted into the system, load SANWatch, click on Storage Manager
icon or select the
Tools > Storage Manager
menu and it should show your
storage pool status as “Online”.
Step 10
. Once your storage pool has been confirm is indeed back online, you may
restore your original settings (please refer to EonStor DS SANWatch User
Manual on Replacing System Configurations) or you can choose to do so,
manually.
118