EonStor DS S48 Series Hardware Manual
iii.
Remove Controller B (indicated by the blue circle shown below) from the
Replacing the Controller Module(s): Single / Dual /
.
Controller A Controller B
2. Power off the RAID system.
3. Press and hold the Restore Default button
(1)
on Controller A. You may use a
straighten paper clip or the tip of a pen to press the button. While pressing the
Restore Default button down, power on the RAID system.
4. When the “
Restore Def.
” LED
(2)
turns on and the “
Default Restored
”
firmware event message appear on the LCD, you may release the Restore
Default button (the system default has been restored).
iv.
Power off the RAID system (refer to
).
v.
Replace Controller A with Controller B (Controller B will be inserted into
Controller A’s slot) While leaving Controller B slot empty with Controller B in slot
A, perform the above steps 1 to 8 to restore Controller B to default settings.
vi.
Put both Controller A and Controller B into their original positions and power up
the system without pressing the Restore Default button.
vii.
To restore previous ID/LUN mapping settings, users may use the following
97