EonStor DS S48 Series Hardware Manual
battery backup unit is capable of sustaining memory in
case of power loss.
Blinking
indicates cached data is being transferred to
the flash module after the occurrence of a power
outage. Once the transfer is done, all LEDs will turn
off.
3. Temp.
Amber
Amber
indicates that the detected CPU/board/chassis
temperature has exceeded the higher temperature
threshold.
OFF
indicates that the detected temperature reading is
within the safe range.
4. CBM
Status
Green
/
Amber
Green
indicates the CBM module is ready. Both a BBU
and flash modules are present.
Amber
indicates CBM failure, meaning either BBU or
flash has failed. When lit, it also indicates either BBU
or a flash is missing in a redundant-controller system.
Blinking green
indicates the BBU is being charged.
OFF
in “G” models means the BBU is not installed.
5. Hst Bsy
Green
Blinking green
indicates traffic on the host bus.
6. Drv Bsy
Green
Blinking green
indicates traffic on the drive channels.
7. Restore
Default
Green
Green
indicates the RAID configuration default has
been successfully restored. The LED state will be
invalidated after a few seconds. Please refer to
Restore Default System Settings
89