EonStor DS S12/S16/S24 Series Hardware Manual
Hardware Connection
In-band over Fibre, SAS, or other host link types, out-of-band via
Ethernet or RS-232C
Configuration on Disk
Configuration data stored on disks so that logical drive assemblies
exist after controller replacement.
Failure Indicator
Faults are indicated via alarm, module LED indicators, LCD panel,
SANWatch Manager, or terminal emulation.
6.1.3
Fault Tolerance for RAID models
Drive S.M.A.R.T Support
Yes, with user-configurable
detect-only, clone and replace, and
perpetual clone functions.
CBM (Cache Backup Module)
Yes
ISEMS (Infortrend Simple Enclosure Management Service)
via I
2
C interface
Yes
Automatic Drive Failure Detection
Yes
Automatic Rebuild on Spare Drives
Yes
Regenerate Logical Drive Parity
Yes
Bad Block Reassignment
Yes
Manual and Automatic Rebuild upon Failed Drive
Replacement
Yes
Manual Clone of Suspected Failed Drive
Yes
Concurrent Rebuild on Multiple Drives in a RAID (0 + 1)
Logical Drive
Yes
Salvage the 2
nd
Temporary Failed Drive in a RAID 1, 3, 5 or 6
Logical Drive
Yes
Salvage the 1
st
Temporary Failed Drive in a RAID 0 Logical
Drive
Yes
6.1.4
Power Supply
S12 and S16 Series
Dual controller model:
100VAC @ 10A
240VAC @ 5A with PFC (auto-switching)
Input Voltage
Single controller model:
100VAC @ 6A
240VAC @ 3A with PFC (auto-switching)
Frequency
47 to 63Hz
Power Consumption
Dual controller model: 530W; idle: 345W; Busy: 367W
153