
EonStor DS S12/S16/S24 Series Hardware Manual
RAID Controller A
RAID Controller B
5. Power off the RAID subsystem.
6. Press and hold the Restore Default button on Controller A. You may use a
straightened paper clip to press the button. While pressing the Restore Default
button down, power on the RAID subsystem.
Restore Default Button/LED
7. When the “
Restore Def.
” LED turns on and the “
Default Restored
” firmware
event message appear, you may release the Restore Default button (the system
default has been restored).
8. Power off the system.
9. Replace Controller A with Controller B (= Controller B will be inserted in Controller
A’s slot and the original Controller B slot will still be empty).
10. Restore default settings for Controller B.
11. Put both Controller A and Controller B into their original positions and power up
the system without pressing the Restore Default button.
12. Restore previous settings using the “
Restore NVRAM from Disks
“or “
Restore
NVRAM from Files
” functions. ID/LUN mapping will be restored.
124