EonStor DS S12/S16/S24 Series Hardware Manual
4.2.2
LED Panel for JBOD Models
Service LED
Power LED
Cooling Fan LED
Thermal LED
System Fault LED
Rotary ID Switch
Mute/Service Button
Name
Color
Status
Service
White
ON
indicates that the system is being
serviced or is requiring services.
OFF
indicates that the system is not being
serviced nor is requiring services.
Power
Green
/
Amber
Green
indicates that the system is powered
properly.
Amber
indicates that there is a power failure
in the system.
Cooling Fan
Green
/
Amber
Green
indicates that the cooling fan is
operating properly.
Amber
indicates that the there is a cooling
fan failure in the system.
Thermal
Green
/
Amber
Green
indicates that the internal
temperature is within the safety threshold.
Amber
indicates that the the internal
temperature has gone over the safety
threshold.
System Fault
Green
/
Green
indicates that the system is operating
109