EonStor DS S12/S16/S24 Series Hardware Manual
Although the cooling modules are fully redundant, it is not advisable to run the
EonStor DS subsystem with a single module for an extended period of time.
Detecting a Failed Cooling Module
If a cooling module fails, the system notifies you through the following indicators:
Cooling fan LEDs located at the rear
FAN0 LED
FAN1 LED
FAN2 LED
FAN3 LED
Audible alarm (See
1.5.4 Audible Alarms
for details)
Firmware utility (See Firmware User Manual in the CD-ROM for details)
SANWatch manager software (See SANWatch User Manual in the CD-ROM for
details)
Replacing the Module
The failed cooling module should be replaced as soon as possible, but only when
you have a replacement module in your hand. Contact technical support for more
details. (See
6.4 Contact Information
for details)
5.5.2
For S12x-Gxxxx Models
Redundant cooling modules
: The system is equipped with three (3)
cooling blowers, one (1) within each cooling module. These cooling modules
control the internal operating temperature and therefore their working
integrity should be maintained at all times.
Detecting a failed cooling module:
If a cooling module fails, system
firmware and SANWatch manager will deliver warning events. The LEDs
located on the module will light red and an audible alarm will be triggered.
142