EonStor DS S12/S16/S24 Series Hardware Manual
3.2.7
Switched Fabric Connection (Single-Controller)
CH0 A112
LD0
LD1
CH1 A112
CH0 B113
CH1 B113
CH0 B114
CH1 B114
CH0 A115
CH0 A115
Standby
IDs
HBA 1
HBA 0
HBA 1
HBA 0
EonPath
EonPath
CH0 A112
CH1 A112
CH0 B114
CH1 B114
CH0 B113
CH1 B113
CH0 A115
CH1 A115
1 2 3 4 5 6
7 8 9101112
A
B
12x
6x
8x
2x
9x
3x
10x
4x
11x
5x
7x
1x
E
thernet
A
12x
6x
8x
2x
9x
3x
10x
4x
11x
5x
7x
1x
C
1 2 3 4 5 6
7 8 9 101112
A
B
12x
6x
8x
2x
9x
3x
10 x
4x
1 1x
5x
7x
1x
Et
he
rn
et
A
1 2x
6x
8x
2x
9x
3x
10x
4x
11 x
5x
7x
1x
C
FC switches
L
og
ic
al A
sso
ci
at
io
n
Channels
Controller A
Host
CH0, CH1, CH2, CH3
Configuration Information
RAID controller
1
Host server
4
Data path connection
Data paths are attached to one or more FC
switches. SAN management measures,
such as switch zoning and port binding,
should be taken to avoid multiple servers
from accessing the same LUN.
Host channel bandwidth
3200 MB/s
Above is the sample drawing showing connections with each SFP port connected to