9 - PART REPLACEMENT
SIR 52 MS52 P/F
EN
9 - Pag. 13 / 16
9.14
PLC BATTERY - REPLACEMENT
Replace the battery every year.
INFORMATION
If the battery is not replaced, the
"PLC/CNC software" data will be deleted.
INFORMATION
When replacing the battery, make sure that the bar feeder is live. Warning: if
the battery is replaced with the bar feeder off, I.E. with PLC not live, the bar
feeder parameters will be cleared from the PLC memory and will have to be
immediately restored.
- Open the cubicle.
- Uplift the small door (A) and remove battery (B) from its housing by disconnecting the
socket.
- Fit the new battery (type: lithium 3.6-volt 1/2 AA): be careful to fit the connector correctly.
- Close door (A).