8 - TROUBLES - CAUSES - CURES
SIR 52 MS52 P/F
8 - Pag. 4 / 10
8.3
DEVICE INTRODUCING BARS INTO GUIDES - PROBLEMS
ERROR CAUSE CURE
Levers stop in a lower
position because they are
misaligned
Adjust the loading levers
BAR DROPS OUTSIDE THE
LOWERING ROLLERS
Torn rollers
Replace the control levers rollers
The cylinder does not work
Check the operation of the levers
control cylinder.
ARMS DO NOT LOWER
Levers are jammed in a high
position.
Check there are no crosswise bars
or folded levers
The lateral cylinders do not
work.
Check the operation of the bar
introducing cylinder.
ARMS DO NOT INTRODUCE
BARS
Levers are misaligned and
interfere with the guiding
sprockets.
Position the levers in the loading
cycle.
CLOSED SPROCKETS
PREVENTING THE BAR FEEDING
Jammed sprockets
Clean and check sprockets, making s
Summary of Contents for SIR52 MS52 P
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 10 14 2 6 TECHNICAL INFORMATION...
Page 24: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 14 14...
Page 50: ...EN 4 HANDLING AND INSTALLATION SIR 52 MS52 P F 4 Pag 22 22...
Page 72: ...EN 5 ADJUSTMENTS AND SETTING UP SIR 52 MS52 P F 5 Pag 22 22...
Page 102: ...EN 6 USE AND OPERATION SIR 52 MS52 P F 6 Pag 30 30...
Page 148: ...EN 9 PART REPLACEMENT SIR 52 MS52 P F 9 Pag 16 16...
Page 174: ...EN 11 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SIR 52 MS52 P F 11 Pag 6 6...
Page 185: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 11 34...
Page 203: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 29 34...
Page 212: ...EN 13 LIST OF AFTER SALES CENTERS SIR 52 MS52 P F 13 Pag 4 4...