(2) Repeat cycles = 3
Designating Constant as Start Delimiter
A start delimiter can be programmed at the first byte in the receive format of a RXD1/RXD2 instruction; the
MicroSmart
will recognize the beginning of valid communication, although a RXD1/RXD2 instruction without a start delimiter can
also be executed.
When a constant value is designated at the first byte of source operand S1, the one-byte data serves as a start delimiter to
start the processing of the received data. The valid start delimiter value depends on the data bits selected in the
Communi-
cation Parameters
dialog box, which is called from
Configure
>
Fun Area Settings
>
Communication
, followed by
selecting
User Protocol
in
Port 1
or
Port 2
list box and clicking the
Configure
button. When 7 data bits are selected as
default, start delimiters can be 00h through 7Fh. When 8 data bits are selected, start delimiters can be 00h through FFh.
Constant values are entered in character or hexadecimal notation into the source data.
A maximum of five RXD1 and five RXD2 instructions with different start delimiters can be executed at the same time.
When the first byte of the incoming data matches the start delimiter of a RXD1/RXD2 instruction, the received data is pro-
cessed and stored according to the receive format specified in the RXD1/RXD2 instruction. If the first byte of the incom-
ing data does not match the start delimiter of any RXD1/RXD2 instruction that is executed, the
MicroSmart
discards the
incoming data and waits for the next communication.
While a RXD1/RXD2 instruction without a start delimiter is executed, any incoming data is processed continuously
according to the receive format. Only one RXD1 and one RXD2 instructions without a start delimiter can be executed at a
time. If start inputs to two or more RXD1/RXD2 instructions without a start delimiter are turned on simultaneously, one at
the smallest address is executed and the corresponding completion output is turned on.
Example:
(1) When a RXD1/RXD2 instruction without a start delimiter is executed
0012h
D20
Repeat 1
0034h
D21
ASCII to Binar y conversion
Repeat 2
“1”
(31h)
“2”
(32h)
2 digits
1st block
“3”
(33h)
“4”
(34h)
2 digits
2nd block
“5”
(35h)
“6”
(36h)
2 digits
3rd block
0056h
D22
Repeat 3
****h
D100
When D100 is designated as the first data register
“0”
(30h)
“1”
(31h)
1st
character
“2”
(32h)
“3”
(33h)
Incoming Data
****h
D100+n
****h
D101
The incoming data is divided, converted, and stored to data registers according to the receive format.
Summary of Contents for FC4A-C10R2
Page 1: ...FC4A SERIES Micro Programmable Logic Controller User s Manual FC9Y B812 ...
Page 6: ...PREFACE 4 FC4A MICROSMART USER S MANUAL ...
Page 94: ...2 MODULE SPECIFICATIONS 2 74 FC4A MICROSMART USER S MANUAL ...
Page 184: ...6 ALLOCATION NUMBERS 6 20 FC4A MICROSMART USER S MANUAL ...
Page 218: ...8 ADVANCED INSTRUCTIONS 8 8 FC4A MICROSMART USER S MANUAL ...
Page 240: ...11 BINARY ARITHMETIC INSTRUCTIONS 11 8 FC4A MICROSMART USER S MANUAL ...
Page 244: ...12 BOOLEAN COMPUTATION INSTRUCTIONS 12 4 FC4A MICROSMART USER S MANUAL ...
Page 252: ...13 SHIFT ROTATE INSTRUCTIONS 13 8 FC4A MICROSMART USER S MANUAL ...
Page 274: ...15 WEEK PROGRAMMER INSTRUCTIONS 15 8 FC4A MICROSMART USER S MANUAL ...
Page 378: ...22 DUAL TEACHING TIMER INSTRUCTIONS 22 4 FC4A MICROSMART USER S MANUAL ...
Page 386: ...23 INTELLIGENT MODULE ACCESS INSTRUCTIONS 23 8 FC4A MICROSMART USER S MANUAL ...
Page 408: ...24 ANALOG I O CONTROL 24 22 FC4A MICROSMART USER S MANUAL ...
Page 426: ...26 COMPUTER LINK COMMUNICATION 26 6 FC4A MICROSMART USER S MANUAL ...