Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
406E 0EB9 Attention line 8 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406E 0EBA Attention line 9 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406E 0EBB Attention line 10 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406E 0EBC Attention line 11 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406E 0EE1 Service processor firmware: invalid MRU to FRU
mapping.
1. Check for system firmware updates.
2. Call service support.
406E 0EE2 Service processor firmware fault
1. Check for system firmware updates.
2. Call service support.
406E 0EE5 Firmware error, no callout available
1. Check for system firmware updates.
2. Call service support.
406F 0001 Scan interface basic assurance tests detected a
CEC backplane fault.
CEC backplane
Location code: U0.1-P1
406F 0002 CEC backplane fault
1. Check JTAG cable connections.
2. CEC backplane
Location code: U0.1-P1
406F 0003 Scan interface basic assurance tests detected
processor fault.
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C1
406F 0004 Processor fault
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C2
406F 000E Processor capacity card
Operator panel
Location code: U0.1-L1
406F 0010 DIMM fault
DIMM
Location code: U0.1-P1-C1-M8
406F 0011 DIMM fault
DIMM
Location code: U0.1-P1-C1-M6
406F 0012 DIMM fault
DIMM
Location code: U0.1-P1-C1-M1
406F 0013 DIMM fault
DIMM
Location code: U0.1-P1-C1-M3
406F 0014 DIMM fault
DIMM
Location code: U0.1-P1-C1-M7
406F 0015 DIMM fault
DIMM
Location code: U0.1-P1-C1-M5
406F 0016 DIMM fault
DIMM
Location code: U0.1-P1-C1-M2
406F 0017 DIMM fault
DIMM
Location code: U0.1-P1-C1-M4
Chapter 5. Error code to FRU index
195
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...