Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
4065 00B3 Processor/VPD problem detected
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
4065 00B4 Processor/VPD problem detected
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
4065 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
4065 00D1 Informational message
Informational message
4065 0100 Memory extender 0 on processor card 1
Processor card,
Location code: U0.1-P1-C1
4065 0101 Memory extender 2 on processor card 1
Processor card,
Location code: U0.1-P1-C1
4065 0130 Memory extender 0 on processor card 2
Processor card,
Location code: U0.1-P1-C2
4065 0131 Memory extender 2 on processor card 2
Processor card,
Location code: U0.1-P1-C2
4065 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, and then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
4065 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
4065 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
CEC backplane, U0.1-P1.
4065 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
CEC backplane, U0.1-P1.
4065 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1.
4. Call service support.
4065 0B03 Problem with internal RIO interface (I/O slot 0,
I/O port 3)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1.
4. Call service support.
4065 0B40 Problem with controller chip on CEC backplane
1. CEC backplane, U0.1-P1.
2. Call service support.
Chapter 5. Error code to FRU index
159
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...