Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Number
of
beeps/symptom
FRU/action
5
short,
1
long
(No
memory
found
in
system)
1.
Install
or
reseat
memory,
then
perform
a
blade
server
reset.
2.
DIMMs.
3.
Processor
board.
6
short,
1
long
(Memory
is
not
DDR
type)
1.
Replace
with
supported
DIMMs.
2.
DIMMs.
3.
Processor
board.
7
short,
1
long
(SMBUS
error.
Memory
enumerations
cannot
proceed.)
1.
Processor
board
2.
I/O
board
Baseboard
management
controller
(BMC)
beep
codes
The
following
table
lists
the
BMC
error
beep
codes.
Beep
code/symptom
FRU/action
1-5-1-1
(Microprocessor
failure)
1.
Microprocessor
2.
Processor
board
1-5-2-2
(No
microprocessors)
1.
Microprocessor
2.
Processor
board
1-5-2-3
(VID
mismatch,
population
rules
violation,
microprocessor
mismatch)
1.
Make
sure
all
microprocessors
are
supported
by
the
BIOS
and
of
the
same
family,
model,
stepping,
speed,
and
cache
size.
2.
Microprocessor.
1-5-4-2
(Power
fault:
dc
power
unexpectedly
lost)
1.
Reseat
blade
server
and
power
cycle
the
blade
server.
2.
Reseat
dc
power
cable.
3.
Processor
board.
4.
I/O
board.
1-5-4-4
(Power
control
fault)
1.
Reseat
blade
server
and
power
cycle
the
blade
server.
2.
Flex
cable.
3.
Auxiliary
power
cable.
4.
Processor
board.
5.
I/O
board.
No-beep
symptoms
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
No-beep
symptom
FRU/action
No
beep
and
no
video
(System
error
LED
is
OFF)
See
“Undetermined
problems”
on
page
101.
No
beep
and
no
video
(System
Attention
LED
is
ON)
See
“Diagnosing
problems
using
the
light
path
diagnostics
feature”
on
page
27.
78
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for HS40 - BladeCenter - 8839
Page 1: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 42: ...32 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 86: ...76 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 114: ...104 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 131: ...Appendix B Safety information 121...
Page 132: ...122 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 133: ...Appendix B Safety information 123...
Page 134: ...124 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 135: ...Appendix B Safety information 125...
Page 136: ...126 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 137: ...Appendix B Safety information 127...
Page 149: ...Appendix B Safety information 139...
Page 150: ...140 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Safety information 141...
Page 152: ...142 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...Appendix B Safety information 143...
Page 154: ...144 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 166: ...156 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 171: ......
Page 172: ...Part Number 25K8105 Printed in USA 1P P N 25K8105...