To
use
SCSI
hard
disk
drives
with
your
blade
server,
install
a
SCSI
storage
expansion
unit,
such
as
the
IBM
BladeCenter
SCSI
Storage
Expansion
Unit,
on
the
blade
server.
You
will
then
be
able
to
install
two
3.5-inch,
hot-swap,
SCSI,
1-inch
(26
mm)
slim-high
hard
disk
drives
in
the
expansion
unit,
for
use
by
the
blade
server.
The
SCSI
controller
in
the
BladeCenter
SCSI
storage
expansion
unit
supports
embedded
mirroring,
which
is
similar
to
RAID
level-1.
Important:
To
avoid
potential
performance
and
reliability
problems
when
configuring
or
replacing
drives
in
a
mirrored
configuration,
make
sure
that
the
storage
capacities
and
speeds
of
the
drives
are
identical.
After
you
install
the
SCSI
storage
expansion
unit
on
your
blade
server,
the
blade
server
and
expansion
unit
are
a
unit
that
occupies
three
blade
bays
in
the
BladeCenter
unit.
Attention:
To
ensure
proper
cooling
and
system
reliability,
make
sure
that
each
of
the
SCSI
hard
disk
drive
bays
on
the
SCSI
storage
expansion
unit
contains
either
a
hot-swap
SCSI
hard
disk
drive
or
a
filler
panel.
Complete
the
following
steps
to
install
the
SCSI
storage
expansion
unit.
Note:
The
illustrations
used
in
this
procedure
depict
the
installation
process
on
a
BladeCenter
HS40
blade
server
in
a
BladeCenter
Type
8677
unit.
These
illustrations
might
differ
slightly
from
your
hardware.
However,
this
installation
process
is
the
same
regardless
of
the
BladeCenter
unit.
1.
Review
the
safety
information
beginning
on
page
109
and
“Installation
guidelines”
on
page
33.
2.
Shut
down
the
operating
system,
turn
off
the
blade
server,
and
remove
the
blade
server
from
the
BladeCenter
unit
(see
“Removing
the
blade
server
from
the
BladeCenter
unit”
on
page
39
for
instructions).
3.
Carefully
lay
the
blade
server
on
a
flat,
nonconductive
surface.
52
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for HS40 - BladeCenter - 8839
Page 1: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 42: ...32 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 86: ...76 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 114: ...104 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 131: ...Appendix B Safety information 121...
Page 132: ...122 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 133: ...Appendix B Safety information 123...
Page 134: ...124 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 135: ...Appendix B Safety information 125...
Page 136: ...126 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 137: ...Appendix B Safety information 127...
Page 149: ...Appendix B Safety information 139...
Page 150: ...140 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Safety information 141...
Page 152: ...142 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...Appendix B Safety information 143...
Page 154: ...144 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 166: ...156 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 171: ......
Page 172: ...Part Number 25K8105 Printed in USA 1P P N 25K8105...