Replacing
a
SCSI
hot-swap
hard
disk
drive
If
a
hard
disk
drive
in
the
storage
expansion
unit
fails,
you
can
replace
it
without
turning
off
the
blade
server.
Complete
the
following
steps
to
replace
a
SCSI
hot-swap
hard
disk
drive
in
a
storage
expansion
unit
hot-swap
bay.
Note:
The
illustrations
used
in
this
procedure
depict
the
installation
process
on
a
BladeCenter
HS40
blade
server
in
a
BladeCenter
Type
8677
unit.
These
illustrations
might
differ
slightly
from
your
hardware.
However,
this
installation
process
is
the
same
regardless
of
the
BladeCenter
unit.
Blade server
Filler panel
Hard disk drive
Storage
expansion unit
Attention:
To
maintain
proper
system
cooling,
do
not
operate
the
BladeCenter
unit
for
more
than
1
minute
without
either
a
hot-swap
hard
disk
drive
or
a
filler
panel
installed
in
each
storage
expansion
unit
bay.
1.
Review
the
safety
information
beginning
on
page
109
and
“Installation
guidelines”
on
page
33.
2.
Locate
the
defective
hard
disk
drive
(look
for
an
amber
status
LED
on
the
front
of
the
hard
disk
drive).
3.
Make
sure
that
the
hard
disk
drive
has
stopped
spinning.
4.
Move
the
handle
on
the
hard
disk
drive
to
the
open
position
(perpendicular
to
the
hard
disk
drive),
and
pull
the
hot-swap
hard
disk
drive
assembly
from
the
bay.
5.
Within
1
minute,
install
the
replacement
hard
disk
drive
in
the
hot-swap
bay
(see
“Installing
a
SCSI
hot-swap
hard
disk
drive”
on
page
57
for
instructions).
Replacing
the
battery
IBM
has
designed
this
product
with
your
safety
in
mind.
The
lithium
battery
must
be
handled
correctly
to
avoid
possible
danger.
If
you
replace
the
battery,
you
must
adhere
to
the
following
instructions.
Note:
In
the
U.
S.,
call
1-800-IBM-4333
for
information
about
battery
disposal.
If
you
replace
the
original
lithium
battery
with
a
heavy-metal
battery
or
a
battery
with
heavy-metal
components,
be
aware
of
the
following
environmental
consideration.
Chapter
4.
Installing
options
59
Summary of Contents for HS40 - BladeCenter - 8839
Page 1: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 42: ...32 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 86: ...76 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 114: ...104 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 131: ...Appendix B Safety information 121...
Page 132: ...122 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 133: ...Appendix B Safety information 123...
Page 134: ...124 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 135: ...Appendix B Safety information 125...
Page 136: ...126 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 137: ...Appendix B Safety information 127...
Page 149: ...Appendix B Safety information 139...
Page 150: ...140 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Safety information 141...
Page 152: ...142 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...Appendix B Safety information 143...
Page 154: ...144 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 166: ...156 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Page 171: ......