76
IBM® xSeries 360: User’s Reference
c.
To attach the replacement diskette drive to the tray, reverse these steps.
6.
To detach the CD-ROM drive from the tray:
a.
Release the CD-ROM drive retention spring on the left side of the tray and
slide the CD-ROM drive toward the front of the tray. As you remove the drive,
it unplugs from the media interposer card.
b.
To attach the replacement CD-ROM drive to the tray, reverse these steps.
7.
Side the tray into the bay and press the media tray release knob to secure it to the
frame.
8.
Reconnect the wide cable between the media interposer card and the hard disk
drive backplane.
9.
If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation” on page 86.
Installing memory modules
The server supports up to four pairs of DIMMs and supports memory interleaving.
Adding memory to the server is an easy way to make programs run faster.
Notes:
1.
The server supports a minimum of 512 MB of system memory and a maximum of
8 GB of system memory. The DIMM slots are arranged in two columns of four
rows each. The server supports DIMMs of 256 MB, 512 MB, and 1 GB capacities.
2.
Each pair of DIMMs must be the same type, capacity, and speed. However, you
can install DIMM pairs of different capacities as long as both DIMMs in each pair
are the same.
3.
Installing or removing DIMMs changes the configuration information in the server.
Therefore, after installing or removing DIMMs, you must save the new
configuration information using the Configuration/Setup Utility program. When
you restart the server, the system displays a message indicating that the memory
configuration has changed. Start the Configuration/Setup Utility program and
select
Save Settings.
See Chapter 3, “Configuring the server,” on page 13 for
more information.
Complete the following steps to install the DIMMs:
1.
Review the safety precautions beginning on page 53, “Handling static-sensitive
devices” on page 52, and the documentation that comes with the DIMMs.
2.
Turn off the server, disconnect all power cords and external cables, and remove
the top cover (see “Removing the server top cover and bezel” on page 66).
Note:
If the server had a DIMM failure, a DIMM LED on the memory board
indicates the failing module.
Summary of Contents for Eserver xSeries 360 Type 8686
Page 1: ...User s Reference xSeries 360 Type 8686...
Page 2: ......
Page 3: ...IBM IBM xSeries 360 User s Reference...
Page 8: ...vi IBM xSeries 360 User s Reference...
Page 14: ...xii IBM xSeries 360 User s Reference...
Page 64: ...50 IBM xSeries 360 User s Reference...
Page 108: ...94 IBM xSeries 360 User s Reference...
Page 162: ...148 IBM xSeries 360 User s Reference...
Page 183: ......
Page 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...