Chapter 6. Solving Problems
139
0x0E
Explanation:
Could not allocate enough memory for receive queue.
For Windows NT:
Action:
1.
From the Windows NT desktop, click
Start
→
Control Panel
→
Networks
→
Adapters
.
2.
Select an IBM Ethernet adapter from the list.
3.
Click
Properties
→
Advanced
.
4.
Lower the value for the resource named in the message.
For Windows 2000:
Action:
1.
From the Windows 2000 desktop, click
Start
→
Settings
→
Control Panel
→
Network and
Dial-up Connections
.
2.
Right-click an IBM Ethernet adapter in the list and click
Properties
.
3.
Select a component and click
Configure
.
4.
Click the
Advanced
tab and lower the value for the resource named in the message.
0x0F
Explanation:
Could not allocate enough memory for other structures.
For Windows NT:
Action:
1.
From the Windows NT desktop, click
Start
→
Control Panel
→
Networks
→
Adapters
.
2.
Select an IBM Ethernet adapter from the list.
3.
Click
Properties
→
Advanced
.
4.
Lower the resource values that apply to the transmit queue.
For Windows 2000:
Action:
1.
From the Windows 2000 desktop, click
Start
→
Settings
→
Control Panel
→
Network and
Dial-up Connections
.
2.
Right-click an IBM Ethernet adapter in the list and click
Properties
.
3.
Select a component and click
Configure
.
4.
Click the
Advanced
tab and lower the resource values that apply to the transmit queue.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the required ID.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled.
0x13
Explanation:
Did not find any Ethernet controllers that matched the required subven/subdev.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled.
0x16
Explanation:
Single adapter found, but multiple instances tried to load.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled, and that
the integrated 10/100 Ethernet controller or the optional Ethernet PCI adapter are enabled.
0x17
Explanation:
Slot parameter not specified in the registry.
Action:
Remove the adapter driver and reinstall it. If the problem remains, call for service.
Table 19. NDIS (Windows 2000 or Windows NT) driver messages for the Ethernet controller.
Error code (hex)
Description
Summary of Contents for Eserver xSeries 360 Type 8686
Page 1: ...User s Reference xSeries 360 Type 8686...
Page 2: ......
Page 3: ...IBM IBM xSeries 360 User s Reference...
Page 8: ...vi IBM xSeries 360 User s Reference...
Page 14: ...xii IBM xSeries 360 User s Reference...
Page 64: ...50 IBM xSeries 360 User s Reference...
Page 108: ...94 IBM xSeries 360 User s Reference...
Page 162: ...148 IBM xSeries 360 User s Reference...
Page 183: ......
Page 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...