8
IBM® xSeries 360: User’s Reference
USB port:
This port enables you to attach a USB device to the front of the server.
SCSI bus activity LED:
This green LED is on when there is activity on the SCSI bus.
Information LED:
This amber light is on if the server power supplies are
nonredundant or some other noncritical event has occurred. See the LEDs on the
Level 2 diagnostic LED panel or on the system board for specific error information.
For details, see “Level 2 diagnostic LED panel and system board LED locations” on
page 63.
Fault LED:
This amber LED is on if a system error has occurred. See the LEDs on
the Level 2 diagnostic LED panel or on the system board for specific error information.
For details, see “Level 2 diagnostic LED panel and system board LED locations” on
page 63.
Reset button:
Press this button to reset the server and run the power-on self-test
(POST).
Power-control button:
If the server is in operational mode, press this button to put it
into standby mode. If the server is in standby mode, press this button to restore it to
operational mode. See “Turning on the server” and “Turning off the server” on page 9
for more information about applying and removing external power to the server.
Power LED:
This green LED is on if ac and dc power are present in the server. If this
LED is flashing, the server is in standby mode (ac power is present, but the power
supplies are turned off). If this LED is off, either ac power, all power supplies, or the
light has failed.
Note:
If this LED is off, it does not mean that there is no electrical power present in
the server. The LED might be burned out. To remove all electrical current
from the server, you must unplug the server power cords from the electrical
outlets.
Turning on the server
Turning on the server refers to the act of plugging the server power cords into the
power source and pressing the power-control button. After you install the network
operating system in the server, this typically causes the operating system to start.
Complete the following steps to turn on the server.
1.
Turn on all external devices, such as the monitor.
Note:
After you plug the power cords into the power source, wait 30 seconds
before pressing the power-control button on the operator information
panel. During this time, the Remote Supervisor Adapter is initializing and
the power-control button does not respond. The power LED on the
information panel blinks, indicating that ac power is present in the server.
2.
Plug the server power cords into the power source.
Note:
Plugging the power cords into the power source might cause the server to
start automatically. This is an acceptable action.
3.
Wait 30 seconds; then, press the power-control button on the operator information
panel. The power LED comes on and the power-on self-test (POST) begins.
If the server is turned on and a power failure occurs, it restarts automatically when
power is restored. You can turn on the server remotely by means of the Remote
Supervisor Adapter.
Summary of Contents for Eserver xSeries 360 Type 8686
Page 1: ...User s Reference xSeries 360 Type 8686...
Page 2: ......
Page 3: ...IBM IBM xSeries 360 User s Reference...
Page 8: ...vi IBM xSeries 360 User s Reference...
Page 14: ...xii IBM xSeries 360 User s Reference...
Page 64: ...50 IBM xSeries 360 User s Reference...
Page 108: ...94 IBM xSeries 360 User s Reference...
Page 162: ...148 IBM xSeries 360 User s Reference...
Page 183: ......
Page 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...