Note
Due to the background registration technique the persons, who remain in the same pos-
ition, without moving, for an extended period of time will not be detected.
To configure CrossWire alarm, do the following:
1.
Choose CrossWire in the Alarm menu
2.
Choose the CrossWire
drawing tool
3.
Draw the detection zone in the live-view window. A total of three CrossWire detection
alarm zones can be drawn.
a.
Click on the live view screen to define the starting point
b.
Hold down the left mouse button and drag the cursor to set the end point. The arrow
in the middle should point in the desired location.
c.
To adjust the detection zone position on the screen, click on the desired detection
zone, hold the left mouse button down and drag the selected zone to the desired
position.
d.
To adjust the detection zone, click on start/end point, hold down the left mouse
button and drag in desired location to expand/shrink or change the direction of the
CrossWire detection zone
e.
Click Undo to delete the last detection zone
f.
Click Clear to delete all detection zones for the selected camera
g.
Name the detection zone in the Area field if desired
4.
Repeat steps 4-6 of the Area alarm setup
Configuring Idle alarm
The Idle alarm detects a human/vehicle/object and initiates an alarm if the detected object remains
in the defined area for a period of time longer than that defined by user.
Please note that the Idle alarm option will not be available for the overhead-mounted cameras
and in the crowded locations.
To configure Idle alarm, do the following:
1.
Choose Idle in the Alarm menu
2.
Repeat steps 2-6 of the Area alarm setup
3.
Configure the Idle Alarm Setting for the selected detection zone. Set the Period of
Time, in hours, minutes and seconds that an object is allowed to remain in the defined
area. Once the person/vehicle/object stay has exceeded the allowed period of time, the
alarm will be triggered.
In the example below, the alarm will be triggered if the person remains in the defined
area for 2 or more minutes.
90
i³Server
XML to PDF by RenderX XEP XSL-FO Formatter, visit us at