l
Click
Apply
. The
Operation Result
dialog box is displayed indicating that the
operation is successful. Click
Close
or
Browse Trail
to query the created VC-4 server
trail.
2.
Create a trunk link.
l
Choose
Service
>
MSTP Trail
>
Create Trunk Link
from the Main Menu.
l
Set
Bandwidth
to
5 X: VC12
. Select
Auto Create Server Trails
.
NOTE
If you do not select
Auto Create Server Trails
, refer to
to create cross-connections of
Ethernet services between NE1 and NE3 to SDH links. Set
Level
to
VC12
. Set
Server Layer
Trail
to the created link when creating trunk links.
l
Configure bound timeslots for the source NE. Click
Browse
. In the dialog box that is
displayed, select NE1 and set
NE Panel
to EFS8,
VCTRUNK Port
to
1
, and
Lower
Order
to VC4:4-VC12:1 to VC4:4-VC12:5. Click
OK
.
l
Configure bound timeslots for the sink NE. Click
Browse
and select NE3. Set
NE
Panel
to EFS8,
VCTRUNK Port
to
1
, and
Lower Order
to VC4:4-VC12:1 to VC4:4-
VC12:5. Click
OK
.
l
Select
Activate the trail
and click
Apply
.
3.
Create EPL services.
l
Choose
Service
>
MSTP Trail
>
Create EPL
from the Main Menu.
l
Double-click NE1 (source) and NE3 (sink) on the main topology to configure the source
and sink of the EPL services.
Table 4-19
Parameters of the EPL services between user A1 and user A2
Parameter
Value in This Example
Source
Port Usage Strategy
Port
Port
NE1-4-EFS8-PORT1
Sink
Port Usage Strategy
Port
Port
NE3-4-EFS8-PORT1
l
Set trunk link routing policies using the existing trunk link. Select the trunk link created
in step 1 b. Click
Next
.
NOTE
l
To create EPL services in end-to-end mode, complete the following recommended steps: first
create a server trail, then create a trunk link, and finally create EPL services. When creating
EPL services, select
Use Existing Trunk Link
.
l
Alternatively, create the trunk link when creating the EPL services. In this case, select
Create
Trunk Link Manually
or
Create Trunk Link Automatically
.
l
In the
Port Attribute Setting
dialog box, set port attributes.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-58
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)