Parameter
NE1
EVPL1
(PORT1
←→
VCTRUNK1)
EVPL2
(PORT1
←→
VCTRUNK2)
Service Direction
Bidirectional
Source Port
PORT1
PORT1
Source C-VLAN (e.g. 1,3-6) 100
200
Sink Port
VCTRUNK1
VCTRUNK2
Sink C-VLAN (e.g. 1,3-6)
100
200
4.6.3 Configuration Process
Ethernet switching boards are required for creating EVPL services of different VLAN IDs on
NE1. In this way, the data of different users received from the same external port can be
differentiated. Ethernet transparent transmission boards are required for creating EPL
transparent transmission services on NE2 and NE4.
Prerequisite
You must be familiar with
4.3.2 Flow of Configuring EVPL Services
Background Information
If the Ethernet boards in the actual application scenarios are different from the boards in this
example, you need to learn about the requirements for configuring specific boards.
l
For the EVPL services supported by Ethernet switching boards, see
l
For the VCTRUNK binding requirements of Ethernet switching boards, see
Requirements for Binding Paths with VCTRUNKs on Ethernet Boards
.
Procedure
Step 1
Configure the EVPL services for user C1 on NE1.
1.
Set the attributes of the external port (PORT1 of the EFS8 board) used by the service of
user C1.
l
In the NE Explorer, select the EFS8 board, and then choose
Configuration
>
Ethernet
Interface Management
>
Ethernet Interface
from the Function Tree.
l
Select
External Port
.
l
Click the
Basic Attributes
tab. After setting the parameters, click
Apply
.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services