User
Paramete
r
Value in
This
Example
Description
Av
aila
ble
Bo
un
d
Pat
hs
Leve
l
VC12-xv
The service between user G1 and user G3 uses
a 10 Mbit/s bandwidth. Hence, five VC-12s
need to be bound.
For the method of computing the bound
timeslots based on the service bandwidth, see
6.3 Ethernet Service Bandwidths Carried
by VCTRUNKs of Ethernet Boards
Serv
ice
Dire
ction
Bidirectio
nal
The service between user G1 and user G3 is a
Bidirectional
service.
Avai
lable
Reso
urce
s
VC4-4
For the resources used by other boards, see
Requirements for Binding Paths with
VCTRUNKs on Ethernet Boards
Avai
lable
Tim
eslot
s
VC12-6 to
VC12-10
Five VC-12s need to be bound for the service
between user G1 and user G3. In this example,
the sixth to the tenth VC-12s need to be
selected in sequence.
User
H1
←→
user H2
Configura
ble Ports
VCTRUN
K3
As shown in
, VCTRUNK3 of the
EFS8 board is used by the service between
user H1 and user H2.
Av
aila
ble
Bo
un
d
Pat
hs
Leve
l
VC12-xv
The service between user H1 and user H2 uses
a 20 Mbit/s bandwidth. Hence, 10 VC-12s
need to be bound.
For the method of computing the bound
timeslots based on the service bandwidth, see
6.3 Ethernet Service Bandwidths Carried
by VCTRUNKs of Ethernet Boards
Serv
ice
Dire
ction
Bidirectio
nal
The service between user H1 and user H2 is a
Bidirectional
service.
Avai
lable
Reso
urce
s
VC4-4
For the resources used by other boards, see
Requirements for Binding Paths with
VCTRUNKs on Ethernet Boards
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.