The following table lists the description of each value.
Value
Description
Clock Source in System
Clock Priority Table
Indicates that the system clock priority table contains the
tributary clock sources, line clock sources, external clock
sources, and internal clock sources.
Configuration Guidelines
The OptiX OSN 550 does not support
External Clock Source
.
Relationship with Other Parameters
None.
Related Information
None.
7.126 S1 Byte Synchronization Quality Information
Description
The
S1 Byte Synchronization Quality Information
parameter indicates the synchronization
quality information in the S1 byte that is output by the current traced synchronous source. The
S1 byte defined by the ITUT is used to transmit the quality information about the clock sources.
It indicates the quality information of 16 types of synchronous sources with bits 5-8 of the S1
byte in the section overhead. With this quality information and certain switching protocols, the
automatic protection switching of the synchronization clock can be realized in the synchronous
network.
Impact on the System
The system running is not affected.
Values
Value Range
Default Value
Synchronous Source
Unavailable, Quality Unknown,
G.811 Reference Clock, G.812
Transit Clock, G.812 Local
Clock, SDH equipment timing
source (SETS) signal
-
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7 List of Parameters
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7-103