User
Parameter
Value in
This
Example
Description
Sink Port
VCTRUN
K1
When creating the bidirectional Ethernet
service from a PORT to a VCTRUNK, it is
recommended that you use a specific
VCTRUNK as the sink port. In this example,
VCTRUNK1 is the internal port used by the
service between user E1 and user E2.
Sink C-
VLAN (e.g.
1, 3-6)
200
According to the plan, the VLAN ID is set to
200 on the transmission network side for
Ethernet service between user E1 and user E2.
4.
Configure the cross-connections from the Ethernet services to the SDH links for user D1
and user E1.
l
In the NE Explorer, select NE1 and then choose
Configuration
>
SDH Service
Configuration
from the Function Tree.
l
Click
Create
on the lower-right pane to display the
Create SDH Service
dialog box.
Set the parameters as follows.
User
Paramete
r
Value in
This
Example
Description
User D1
←→
user D2
user E1
←→
user E2
Level
VC12
The timeslots bound with the service
between user D1 and user D2 and the
service between user E1 and user E2 are at
the VC-12 level. The service level must be
consistent with the level of the paths bound
with the VCTRUNK.
Service
Direction
Bidirectiona
l
The service between user D1 and user D2
and the service between user E1 and user
E2 are bidirectional services.
Source Slot 4-EFS8-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the Ethernet board as the source slot.
Source
VC4
VC4-4
The value range of
Source VC4
is
consistent with the value range of
Available Resources
, which is set for the
paths bound with VCTRUNK1. In this
example,
Source VC4
is set to
VC4-4
.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-81