Figure 4-19
Flow of configuring EVPL services
Start
Configure Ethernet
external ports
Configure Ethernet
internal ports
Create EPL services
Create cross-
connections
End
1
3
2
4
Required
Optional
Check service
continuity
Enable NE
performance
monitoring
Back up NE
configuration data
6
7
8
Configure the QoS
5
Table 4-9
Flow of configuring EVPL services
Step
Operation
Remarks
1
Configuring External Ports on
Ethernet Boards
Required
When an NE accesses Ethernet services through the external
ports on the Ethernet board, you need to configure the
attributes of the external ports so that the external ports can
work with the data communication equipment on the client
side, thus ensuring the normal accessing of the Ethernet
services.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-26
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)