Relationship with Other Parameters
The value range depends on the port rate.
Related Information
Maxpps: indicates the maximum number of frames per second.
Specifically,
l
If the port rate is 10 Mbit/s, the Maxpps value is 14880.
l
If the port rate is 100 Mbit/s, the Maxpps value is 148800.
l
If the port rate is 1000 Mbit/s, the Maxpps value is 1488000.
l
If the port rate is 10 Gbit/s, the Maxpps value is 14880000.
According to the rule of Maxpps/10 <
Error Frame Period Window(Frames)
< Maxpps*60,
you know the value range of the
Error Frame Period Window(Frames)
parameter for a certain
port rate.
7.44 Error Frame Monitor Threshold(Frames)
Description
The
Error Frame Monitor Threshold(Frames)
parameter specifies the received N frames in
which the number of error frames reach the specified upper threshold. In this case, a link event
alarm is reported.
Impact on the System
After you set the
Error Frame Period Window(Frames)
and
Error Frame Period Threshold
(Frames)
parameters, a link event alarm is reported if the number of error frames received within
a certain period reaches the specified upper threshold.
Values
Valid Values
Default Value
Unit
1-892800000, in step length of 1
1
Frame
Configuration Guidelines
None.
Relationship with Other Parameters
None.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7 List of Parameters
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7-41