7.33 CC Status (Ethernet OAM)
Description
The
CC Status (Ethernet OAM)
parameter specifies whether to activate the connectivity check
(CC) function at a maintenance point.
Impact on the System
After the CC function is activated, the maintenance point starts the CC. If the check is initially
successful, the EX_ETHOAM_CC_LOS alarm is reported if a CC failure occurs later.
Values
Valid Values
Default Value
Activate, Inactivate
Inactivate
Configuration Guidelines
To start the connectivity check, activate the CC function at a maintenance endpoint.
To stop the connectivity check, deactivate the CC function.
Relationship with Other Parameters
The CC function can be activated at a maintenance endpoint only.
7.34 Test Result (LB and LT Test)
Description
The
Test Result (LB and LT Test)
parameter specifies the result derived from the LB or LT
test each time.
Impact on the System
The system operation is not affected.
Values
Valid Values
Default Value
Succeeded, Failed
-