Impact on the System
The system operation is not affected.
Values
Valid Values
Default Value
SERIALx, Bid-BidType-
PortID
-
The following table lists the description of each value.
Value
Description
SERIALx
Indicates the local broadcast data port,
for example, SERIAL1.
Bid-BidType-PortID
Indicates a port that is used to set a slot of the F1 data port.
Configuration Guidelines
Select the value according to the configuration.
Relationship with Other Parameters
If the S1 byte, the S4 byte, or an optical interface is set to transparently transmit DCC overhead,
the broadcast data service may fail to be set.
7.112 External Clock Output Mode When 2M Output
Synchronous Source Is Invalid
Description
The External Clock Output Mode When 2M Output Synchronous Source Is Invalidparameter is
used to specify an action to control the output mode of external clock source when all the clock
sources in the 2M phase-locked source priority table become invalid or when the clock quality
of the selected source is inferior to the output quality threshold of external clock source.
Impact on the System
The system running is not affected.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7 List of Parameters
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7-89