User
Paramete
r
Value in
This
Example
Description
Source
Timeslot
Range(e.g.
1,3-6)
1-10
The value range of the source timeslots is
consistent with the value range of
Available Timeslots
, which is set for the
paths bound with VCTRUNK1. In this
example, the value range of
Available
Timeslots
is from VC12-1 to VC12-10.
Sink Slot
6-SL4D-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the line board as the sink slot.
Sink VC4
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
Sink
Timeslot
Range(e.g.
1,3-6)
1-10
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of sink timeslots must be, however,
consistent with the number of sink
timeslots.
Activate
Immediatel
y
Yes
-
Step 2
Configure the EVPL service on NE2.
Refer to
and configure the EVPL service of NE2.
Step 3
Check whether the services are configured correctly. For the operation procedures, see Testing
Ethernet Service Channels.
l
Test the service connectivity between user D1 and user D2.
l
Test the service connectivity between user E1 and user E2.
Step 4
Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5
Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see
.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-82
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)