l
The Ethernet LAN service of user F occupies the first to fifth VC-12 timeslots of the first
VC-4 (VC4-1:VC12:1-5) on the SDH link from NE1 to NE2 and the first to fifth VC-12
timeslots of the first VC-4 (VC4-1:VC12:1-5) on the SDH link from NE1 to NE4.
l
The Ethernet LAN service from NE1 to NE2 is added and dropped by using the first to fifth
VC-12 timeslots of the fourth VC-4 (VC4-4:VC12:1-5) on the EFS8 board of NE1 and the
first to fifth VC-12 timeslots of the fourth VC-4 (VC4-4:VC12:1-5) on the EGT1 board of
NE2.
l
The Ethernet LAN service from NE1 to NE4 is added and dropped by using the sixth to
tenth VC-12 timeslots of the fourth VC-4 (VC4-4:VC12:6-10) on the EFS8 board of NE1
and the first to fifth VC-12 timeslots of the fourth VC-4 (VC4-4:VC12:1-5) on the EGT1
board of NE4.
Table 4-27
Parameters of external ports on the Ethernet boards
Parameter
NE1
NE2
NE4
Board
EFS8
EGT1
EGT1
Port
PORT1
PORT1
PORT1
Enabled/Disabled
Enabled
Enabled
Enabled
Working Mode
Auto-Negotiation
Auto-Negotiation
Auto-Negotiation
Maximum Frame
Length
1522
1522
1522
Entry Detection
Enabled
-
-
TAG
Tag Aware
-
-
Table 4-28
Parameters of internal ports on the Ethernet boards
Parameter
NE1
NE2
NE4
Board
EFS8
EGT1
EGT1
Port
VCTRUNK1
VCTRUNK2
VCTRUNK1
VCTRUNK1
Mapping
Protocol
GFP
GFP
GFP
GFP
Entry Detection
Enabled
Enabled
-
-
TAG
Tag Aware
Tag Aware
-
-
Bound Path
VC4-4:VC12-1
-VC12-5
VC4-4:VC12-6
-VC12-10
VC4-4:VC12-1
-VC12-5
VC4-4:VC12-1
-VC12-5
Port Type
UNI
UNI
-
-
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-85