Parameter Value in
This
Example
Description
Sink VC4
VC4-1
It is recommended that you set
Sink Slot
to be the same
as
Source Slot
.
Sink
Timeslot
Range(e.g.
1,3-6)
1-15
The service between user A1 and user B1 uses timeslots
1-15.
Activate
Immediatel
y
Yes
-
Step 3
Configure the EPL services for users A2 and B3 on NE3.
Refer to
and configure the EPL services for users A2 and B2. The parameter values of
user A2 and user B2 must be consistent with the parameter values of user A1 and user B1.
Step 4
Check whether the service between user A1 and user A2 and the service between user B1 and
user B2 are correct. For the operation procedure, see Testing Ethernet Service Channels.
Step 5
Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 6
Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see
.
4.5.4 Configuration Process (End-to-End Mode)
During the configuration of EPL services on Ethernet switching boards, you need to configure
Ethernet private line services. This topic describes the process of configuring EPL services for
Ethernet switching boards in end-to-end mode.
Prerequisite
You must understand the information provided in
4.5.2 Signal Flow and Timeslot
Background Information
If in the actual application you use an Ethernet switching board different from the one described
in this example, learn about the requirements for configuring that specific as follows:
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-56
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)