User
Paramete
r
Value in
This
Example
Description
Sink
Timeslot
Range(e.g.
1,3-6)
1-5
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of source timeslots must be, however, the
same as the number of sink timeslots. For
example, if the source timeslots are five
VC-12s, the sink timeslots must be five
VC-12s.
Activate
Immediatel
y
Yes
-
User B1
Level
VC12
The timeslot bound with the service of user
B1 is at the VC-12 level. The service level
must be consistent with the level of the path
bound with the VCTRUNK.
Service
Direction
Bidirectiona
l
The service of user B1 is a bidirectional
service.
Source Slot 4-EFS8-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the Ethernet board as the source slot.
Source
VC4
VC4-4
The value range of
Source VC4
is
consistent with the value range of
Available Resources
, which is set for the
paths bound with VCTRUNK2. In the case
of VCTRUNK2, the value of
Available
Resources
is VC4-4.
Source
Timeslot
Range(e.g.
1,3-6)
6-15
The value range of the source timeslots is
consistent with the value range of
Available Timeslots
, which is set for the
paths bound with VCTRUNK2. In this
example, the value range of
Available
Timeslots
is from VC12-6 to VC12-15.
Sink Slot
6-SL4D-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the line board as the sink slot.
Sink VC4
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-54
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)