Triggering on Line 71
Table 3-1
Line Numbers per Field for Each TV Standard
TV Standard
Field 1
Field 2
Alt Fld
NTSC
1 to 263
1 to 262
1 to 262
PAL
1 to 313
314 to 625
1 to 313
PAL-M
1 to 313
314 to 625
1 to 313
SECAM
1 to 313
314 to 625
1 to 313
GENERIC
1 to 1024
1 to 1024
1 to 1024 (Vertical)
Line Number Represents Count
In
GENERIC
mode, the line number represents the number of a count instead of
a real line number. This is reflected in the label above the softkey changing from
Line
to
Cnt
. In the
Trigger On
selections,
Field 1
,
Field 2
and
Vertical
are used to
indicate where the counting starts. For an interlaced TV system, the counting
starts from the rising edge of the first vertical serration pulse of Field 1 and/or
Field 2. For a non-interlaced TV system, the counting starts after the rising edge
of the vertical sync pulse.
Figure 3-1
Using Option 005 Enhanced TV/Video Trigger (HP 54602B)
To trigger on a specific line of video
3–6