To connect to other instruments
The rear panel outputs provide an easy way to connect your Option
005-equipped oscilloscope to other instruments such as spectrum analyzers
or frequency counters. To use a frequency counter:
1
Connect the vertical output of the oscilloscope to the counter’s input.
2
Connect the frequency to be measured to channel 1.
3
Press
Autoscale
, then select the trigger source to be
channel 1. Adjust the counter as required.
The amplitude of the vertical output signal is proportional to the amplitude as
displayed on the oscilloscope.
The trigger source selection is the control that determines which channel’s
signal is present at the vertical output (
VERT OUT
) connector on the rear of
the oscilloscope.