2
Measure the power supply voltages at L1, L2, and L3 on the system
board.
The test points are not marked on the system board; see figure below for
location of test points.
Make sure that the voltage measurements are within the following tolerances.
Table 4-13
Power Supply Voltage Tolerances
+
5.1 V
±
150 mV (
+
4.95 V to
+
5.25 V)
+
15.75 V
±
787 mV (
+
14.96 V to
+
16.54 V)
−
15.75 V
±
787 mV (
−
14.96 V to
−
16.54 V)
Low Voltage Power Supply voltage test points
(bottom side of oscilloscope
Figure 4–1
Service
Adjusting the Oscilloscope
4–29
Summary of Contents for HP 54600B
Page 7: ...vi ...
Page 12: ...1 The Oscilloscope at a Glance ...
Page 28: ...2 Operating Your Oscilloscope ...
Page 69: ...2 42 ...
Page 70: ...3 Using Option 005 Enhanced TV Video Trigger HP 54602B ...
Page 148: ...Exploded view of oscilloscope Figure 4 11 Service Replacing Parts in the Oscilloscope 4 59 ...
Page 153: ...4 64 ...
Page 154: ...5 Performance Characteristics ...
Page 175: ...Glossary 8 ...