Channels 1 and 2
Range
2 mV/div to 5 V/div (lower limit is 1 mV/div for the HP 54602B)
Accuracy
1
±
1.9% (HP 54600B, HP 54601B, and HP 54602B)
±
2.4% (HP 54603B)
Verniers
1
Fully calibrated, accuracy about
±
3.5%
Cursor accuracy
1, 2, 3
Single cursor accuracy
vertical accuracy
±
1.2% of full scale
±
0.5% of
position value (HP 54602B at <10 mV/div: vertical accuracy
±
2.4% of full
scale
±
0.5% of position value)
Dual cursor accuracy
vertical accuracy
±
0.4% of full scale
Bandwidth limit
≈
20 MHz
Coupling
Ground, ac, and dc
Inversion
Channel 1 and channel 2
CMRR (common mode rejection ratio)
≈
20 dB at 50 MHz
Channels 3 and 4
(HP 54601B & HP 54602B only)
Range
0.1 V/div and 0.5 V/div ranges
Accuracy
1
±
1.5%
Coupling
Ground and dc
1
When the temperature is within
±
10
°
C from the calibration temperature.
2
Use a full scale of 16 mV for 1 mV/div range for HP 54602B.
Use a full scale of 80 mV for 2 mV/div and 5 mV/div ranges for all other scopes.
3
Tested, see "To verify voltage measurement accuracy," on page 4–7.
Performance Characteristics