Programming the Enhanced Monitor
75
Chapter 3
Comments
•
If a parameter is left off, then all the historical data for all parameters of that
command is erased. For example, if the <blower> parameter is left off of the
HIST:RES:BLOW
command, then ALL of the BLOWer historical data is
erased.
•
These commands are not allowed while the mainframe’s power is off.
Error Conditions
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
SYSTem:ERRor?
query.
Reset Condition
A *RST has no effect on the HISTory subsystem.
Number
Message
Probable Cause
-221
“Settings Conflict”
The mainframe’s power is off.
-224
“Illegal Parameter”
The parameter was not correct.
-311
“Memory error”
The historical data’s memory is not available.