108
Programming the Enhanced Monitor
Chapter 3
STATus:QUEStionable:POWer:LEVel?
<supply>[,MIN|MAX]
The
STATus:QUEStionable:POWer:LEVel?
query returns a floating number
representing the power levels of each power supply in watts.
Parameters
Returned Data
Comments
•
This command is not supported for all power supplies. If the power of the
mainframe is off, this query will return the last measurement made before
power turned off.
Error Conditions
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
SYSTem:ERRor?
query.
Reset Condition
*RST does not affect the status system.
Related
Commands
STATus:QUEStionable:CONDition?, STATus:QUEStionable:EVENt?,
STATus:QUEStionable:ENABle?, STATus:QUEStionable:ENABle
Name
Type
Range
Default
Description
<
supply>
enum.
P24, P12, P5
N2, N5P2, N12
N24, TOTal
none
Indicates which power supply wattage is
being queried. P5 is positive 5 Vdc
supply, N12 is negative 12 Vdc supply,
etc.
optional
parameter
optional
enum.
MIN, MAX
none
When added after
<param>, returns the
maximum and minimum wattage limits.
Type
Range
Default
Description
float32
none
Power level of <
supply>, in Watts.
Number
Message
Probable Cause
-241
“Hardware missing”
Power supply doesn’t support power measurements.