122
Programming the Enhanced Monitor
Chapter 3
STATus:QUEStionable:VOLTage:LEVel? <
supply
>[,MIN|MAX]
The
STATus:QUEStionable:VOLTage:LEVel?
query returns a floating number
representing the last measurement of the power supply voltage.
Parameters
Returned Data
Comments
•
The measurement returned is the last measurement made on the supply
identified with <supply>. Under normal operation, this should be within the
last 2 seconds. Voltage is not measured during a *TST? or CAL? operation, so
a query to
STAT:QUES:VOLT:LEV?
will return the last measurement made
before the long operation was entered. If the power of the mainframe is off,
this query will return the last measurement made before power turned off.
•
The optional MIN and MAX parameter allows the power supply’s voltage
limits to be queried.
STAT:QUES:VOLT:LEV? P5, MAX
will return the limit
warning point for the 5V supply.
Reset Condition
*RST does not affect the status system.
Related
Commands
STATus:QUEStionable:VOLTage:EVENt?,
STATus:QUEStionable:VOLTage:CONDition?,
STATus:QUEStionable:VOLTage:ENABle?,
STATus:QUEStionable:VOLTage:ENABle
Name
Type
Range
Default
Description
<
supply>
enumerated P24, P12, P5,
N2, N5PT2, N12
N24, P5STby, P5EXt
none
Indicates which power supply
current is being queried
optional
parameter
optional
enumerated
MIN, MAX
none
When added after <
supply>,
queries the maximum and
minimum voltage limits.
Type
Range
Default
Description
float32
None
power-supply voltage