124
Programming the Enhanced Monitor
Chapter 3
STATus:SCONdition?
The
STATus:SCONdition?
query returns two integers indicating the pass/fail
condition in the Enhanced Monitor. The integers are the sum of the decimal values
of the bits that are set. A returned value of 0 in both integers indicates that there are
no failures. A value of 1 (one) in a bit indicates that the corresponding present
condition has failed. Unused bits return 0. Reading the condition does not clear the
failure.
Returned Data
Type
Range
Default
Decimal
Weight
Description
uint32
0 to
2147483647
none
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
Bit 0: Maintenance Counter Expired
Bit 1: +5V Power Supply Voltage out of limit
Bit 2: +12V Power Supply Voltage out of limit
Bit 3: -12V Power Supply Voltage out of limit
Bit 4: +24V Power Supply Voltage out of limit
Bit 5: -24V Power Supply Voltage out of limit
Bit 6: -5.2V Power Supply Voltage out of limit
Bit 7: -2V Power Supply Voltage out of limit
Bit 8: +5V STby Power Supply Voltage out of limit
Bit 9: +5V Power Supply Current out of limit
Bit 10: +12V Power Supply Current out of limit
Bit 11: -12V Power Supply Current out of limit
Bit 12: +24V Power Supply Current out of limit
Bit 13: -24V Power Supply Current out of limit
Bit 14: -5.2V Power Supply Current out of limit
Bit 15: -2V Power Supply Current out of limit
Bit 16: Slot 0 Temperature over limit
Bit 17: Slot 1 Temperature over limit
Bit 18: Slot 2 Temperature over limit
Bit 19: Slot 3 Temperature over limit
Bit 20: Slot 4 Temperature over limit
Bit 21: Slot 5 Temperature over limit
Bit 22: Slot 6 Temperature over limit
Bit 23: Slot 7 Temperature over limit
Bit 24: Slot 8 Temperature over limit
Bit 25: Slot 9 Temperature over limit
Bit 26: Slot 10 Temperature over limit
Bit 27: Slot 11 Temperature over limit
Bit 28: Slot 12 Temperature over limit
Bit 29: Ambient Temperature over limit
Bit 30 Power Supply Temperature over limit
Bit 31: Not Used; set to 0.
uint32
0 to 31
none
1
2
4
8
16
32
Bit 0: Total power
Bit 1: Blower 1 (main cooling fan)
a
Bit 2: Blower 2 (1
st
Power Supply cooling fan)
a
Bit 3: Blower 3 (2
nd
Power Supply cooling fan)
a
Bit 4: 5V External Voltage
Bit 5 through Bit 31: Not used; set to 0.
a. Fan is operating out of expected range for the present level.