Fabric OS 5.3.0 administrator guide
57
The following example shows the SYSLOG (system message log) output for audit logging.
Shutting down switches and Directors
To avoid corrupting your file system, it is recommended that you perform graceful shutdowns of switches
and Directors.
To power off a Director gracefully (Prior to 5.1.0)
For Directors running Fabric OS versions
prior
to 5.1.x, the following procedure describe how to gracefully
shut down a Director:
1.
Verify which CP is the active CP, and log in to the active CP using a Serial Console connection.
2.
On the standby CP, set the slider switch to the off position, or eject the standby CP from the chassis. This
disables the standby CP.
3.
Enter the
reboot
command from the active CP. This will gracefully take down the system.
4.
When you see the “Press escape within 4 seconds to enter boot interface” message, press
ESC
to
suspend the active CP.
5.
Power off the chassis by flipping both AC power switches to “0” (LEDs inside AC power switches should
turn off). To maintain the ground connection, leave both power cords connected to the chassis and to
an electrical outlet.
For both switches and Directors running Fabric OS 5.1.0 and later, it is recommended that you use the
following graceful shutdown procedures.
To power off a switch gracefully (5.1.0 and later)
1.
Connect to the switch and log in as admin.
2.
Enter the
sysShutdown
command.
3.
At the prompt, type
y.
4.
Wait until the following message displays:
5.
Power off the switch.
Jun 2 08:33:04 [10.32.220.7.2.2] raslogd: AUDIT, 2006/06/02-15:25:53,
[SULB-1003], INFO, FIRMWARE, root/root/NONE/console/CLI, ad_0/ras007_chassis, ,
Firmwarecommit has started.
Jun 5 06:45:33 [10.32.220.70.2.2] raslogd: AUDIT, 2006/06/05-13:38:17,
[CONF-1010], INFO, CONFIGURATION, root/root/NONE/
console/CLI, ad_0/ras070, , configDownload failed
Jun 5 08:15:32 [10.32.248.73.2.2] raslogd: AUDIT, 2006/06/05-13:38:17,
[SEC-1000], WARNING, SECURITY, JaneDoe/root/192.168.132.19/
telnet, Domain A/DoeSwitch, , Incorrect password during login attempt.
switch:admin>
sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?
y
Broadcast message from root (ttyS0) Wed Jan 25 16:12:09 2006...
The system is going down for system halt NOW !!
INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
Unmounting all filesystems.
The system is halted
flushing ide devices: hda
Power down.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...