410 Configuring and monitoring FCIP tunneling
For example, to delete the IPSec policy number 10:
Configuring FCIP Tunnels
You can create only one FCIP tunnel on a given pair of IP address interfaces (local and remote). You can
create multiple FCIP tunnels on a single IP interface if either the local or remote IP interface is unique and
does not have any other FCIP tunnel on it. When the GbE port has a valid SFP and is physically connected
to any other GbE port, the status output from the
switchShow
command is online.
Due to an IPSec RASlog limitation, you may not be able to determine an incorrect configuration that causes
an IPSec tunnel not to become active. This misconfiguration can occur on either end of the tunnel. As a
result, you must correctly match the encryption method, authentication algorithm, and other configurations
for on each end of the tunnel.
NOTE:
The procedures in this section demonstrate configuring FCIP tunnels for remote switches.
The same procedures apply to local switches and need to be performed there as well.
See the
Fabric OS Command Reference Manual
for detailed information on using the commands in this
section.
Following are the steps for configuring an FCIP tunnel:
1.
”
Enabling persistently disabled ports
” on page 402
2.
”
Defining the IP interface of each virtual port
” on page 403
3.
”
Configuring the GbE ports
” on page 404
4.
”
Adding IP routes on a GbE port
” on page 404
5.
”
Verifying IP connectivity
” on page 406
6.
”
Verifying the FCIP tunnel configuration
” on page 413
Before you begin configuring FCIP tunnels, verify that you have an FCIP license installed. See ”
Maintaining
licensed software features
” on page 36.
Enabling persistently disabled ports
Ports on the 400 MP Router and the B-Series MP Router blade are disabled by default. Before you can
configure FCIP tunnels, you must persistently enable the ports.
CAUTION:
VEX_Port Users:
If the fabric is already connected, you must leave the ge0 and ge1 ports
disabled until
after you have configured the VEX_Port;
this will prevent unintentional merging of the two
fabrics.
To enable a persistently disabled port
1.
Enter the
portCfgShow
command to view ports that are persistently disabled.
2.
After identifying the ports, enter the
portCfgPersistentEnable
command to enable the ports.
3.
Disable the port during FCIP configuration by entering the
portDisable
[
slot
/]
port
command.
switch:admin06>
policy --delete ipsec 10
The policy has been successfully deleted.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...