Fabric OS 5.3.0 administrator guide 187
NOTE:
If the CPs fail to synchronize, you can still proceed because the version being tested is
already present on the active CP, and subsequent steps will ensure that the standby CP is updated to
the same version as the active CP
c.
Confirm the evaluation version of firmware is now running on the active CP by entering the
firmwareShow
command.
9.
Update firmware on the standby CP:
a.
Connect to the switch on the standby CP, which is the old active CP.
b.
Enter the
firmwareDownload
-s
command and respond to the prompts.
At this point the firmware should download to the standby CP only and reboot it. The current switch
session will be disconnected.
c.
Wait one minute for the standby CP to reboot, and then connect to the switch and log in as admin.
d.
Enter the
firmwareShow
command to confirm that
both
primary partitions now have the test drive
firmware in place.
You are now ready to evaluate the new version of firmware.
CAUTION:
Stop!
If you want to
restore
the firmware, stop here
and skip ahead to
step 10
; otherwise,
continue to
step 11
to commit the firmware on the switch, which completes the firmware download
operations.
10.
Perform a commit on the standby CP.
From the current switch session on the standby CP, enter the
firmwareCommit
command to update
the secondary partition with new firmware. It takes several minutes to complete the commit operation.
Do no do anything on the switch while this operation is in process.
11.
Perform a commit on the active CP.
a.
From the current switch session on the active CP, enter the
firmwareShow
command and confirm
that only the active CP secondary partition contains the old firmware.
b.
Enter the
firmwareCommit
command to update the secondary partition with the new firmware. It
takes several minutes to complete the commit operation. Do not do anything on the switch while this
operation is in process.
c.
Upon completion of the
firmwareCommit
command, type the
firmwareShow
command to
confirm both partitions on both CPs contain the new firmware.
d.
Enter the
haShow
command to confirm that the HA state is in sync.
CAUTION:
Stop!
If you have completed
step 11
, then you have committed the firmware on both CPs and
you have completed the firmware download procedure. The following
step 12
through
step 14
describe
how to restore the original firmware, and should be performed after step 5.
12.
Restore the firmware on the standby CP.
In the current switch session for the standby CP, enter the
firmwareRestore
command. The standby
CP will reboot and the current switch session will end. Both partitions will have the same Fabric OS
after several minutes.
13.
Perform
haFailover
on the active CP.
a.
In the current switch session for the active CP, enter the
haShow
command to verify that HA
synchronization is complete. It will take a minute or two for the standby CP to reboot and
synchronize with the active CP.
b.
Enter the
haFailover
command. The active CP will reboot and the current switch session will end.
The switch is now running the original firmware.
14.
Restore firmware on the “new” standby CP.
a.
Wait one minute and connect to the switch on the new standby CP, which is the old active CP.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...