Fabric OS 5.3.0 administrator guide 303
In this example, Fabric OS messages map to local7 facility level 7 in the
/etc/syslog.conf
file:
If you prefer to map Fabric OS severities to a different UNIX local7 facility level, see ”
To set the facility
level
” on page 303.
Configuring the switch
Configuring the switch involves specifying syslogd hosts and, optionally, setting the facility level. You can
also remove a host from the list of syslogd hosts.
To specify syslogd hosts
1.
Connect to the switch and log in as
admin
.
2.
Enter the
syslogDipAdd
command and specify an IP address.
3.
Verify that the IP address was entered correctly, using the
syslogDipShow
command.
You can specify up to six host IP addresses for storing syslog messages, as shown in this example:
To set the facility level
1.
Connect to the switch and log in as
admin
.
2.
Enter the following command:
n
is a number from 0 through 7, indicating a UNIX local7 facility. The default is 7.
It is necessary to set the facility level only if you specified a facility other than local7 in the host
/etc/syslog.conf
file.
To remove a syslogd host from the list
1.
Connect to the switch and log in as
admin
.
2.
Enter the
syslogDipRemove
command:
3.
Verify the IP address was deleted using the
syslogDipShow
command.
local7.emerg
/var/adm/swcritical
local7.alert
/var/adm/alert7
local7.crit
/var/adm/crit7
local7.err
/var/adm/swerror
local7.warning
/var/adm/swwarning
local7.notice
/var/adm/notice7
local7.info
/var/adm/swinfo
local7.debug
/var/adm/debug7
switch:admin>
syslogdipadd 10.1.2.1
switch:admin>
syslogdipadd 10.1.2.2
switch:admin>
syslogdipadd 10.1.2.3
switch:admin>
syslogdipadd 10.1.2.4
switch:admin>
syslogdipadd 10.1.2.5
switch:admin>
syslogdipadd 10.1.2.6
switch:admin>
syslogdipshow
syslog.IP.address.1 10.1.2.1
syslog.IP.address.2 10.1.2.2
syslog.IP.address.3 10.1.2.3
syslog.IP.address.4 10.1.2.4
syslog.IP.address.5 10.1.2.5
syslog.IP.address.6 10.1.2.6
switch:admin>
syslogdfacility -l
n
switch:admin>
syslogdipremove 10.1.2.1
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...