270 Administering FICON fabrics
•
Some 1-Gbit/sec storage devices cannot auto-negotiate speed with the 4/256 SAN Director, SAN
Switch 4/32 or SAN Switch 4/32B ports. For these types of devices, configure ports that are
connected to 1-Gbit/sec storage devices for fixed 1-Gbit/sec speed.
Preparing a switch
To verify and prepare a switch for use in a FICON environment, complete the following steps:
1.
Connect to the switch and log in as admin.
2.
If not in a cascaded environment, proceed to
step 3
.
If in a FICON cascaded environment, enter the following commands:
•
licenseShow
to verify that required licenses (Secure Fabric OS and Zoning) are activated
•
secModeShow
to determine if Secure Fabric OS is enabled; if it is disabled, enable it
•
secPolicyShow
to verify that the SCC_POLICY is active
•
pkiShow
to determine the existence of PKI objects, such as switch private key, private key
passphrase, CSR, root certificate, and switch certificate. If none of these objects exists, refer to the
Secure Fabric OS Administrator’s Guide
for information about creating the PKI objects and
obtaining the digital certificate file.
3.
Enter the
switchShow
command to verify that the switch and devices are online.
4.
Change the routing policy on the switch from the default exchange-based policy to the required
port-based policy for those switches with FICON devices directly attached. For the SAN Switch 4/32
and SAN Switch 4/32B, refer to the
Fabric OS Command Reference Manual
for details about the
aptPolicy
command. For the 4/256 SAN Director, refer to the
Web Tools Administrator’s Guide
.
5.
Enter the
ficonshow
rnid
command to verify that the FICON
devices are registered with the switch.
6.
Enter the
ficonshow
lirr
command to verify that the FICON
host channels are registered to listen
for link incidents.
7.
Optionally, refer to ”
Using FICON CUP
” on page 274 for details about using FICON CUP.
Configuring a single switch
Single-switch configuration does not require IDID or fabric binding, provided that connected channels are
configured for single-byte addressing. However, you should configure IDID to ensure that domain IDs are
maintained.
Configuring a high-integrity fabric
To configure a high-integrity fabric (cascaded configuration):
1.
Disable each switch in the fabric.
2.
For each switch:
a.
Enable the IDID flag.
b.
Set the domain ID.
c.
Install security certificates and keys.
3.
Enable the switches; this builds the fabric.
4.
Set up security on the primary FCS switch.
Use the
secModeEnable
command. The security policies are distributed to each switch in the fabric.
(For details on the Quickmode procedure, refer to the
Secure Fabric OS Administrator’s Guide
.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...