176 Installing and maintaining firmware
NOTE:
If you do not know the CP address, use the
ipAddrShow
command to view a list of all CP IP
addresses associated with the switch.
6.
(Optional) Enter the
supportSave
command to capture a snapshot of your configuration and provide
baseline information in case there is a need to troubleshoot or seek advanced support. Make sure that
you enter this command on the standby CP as well.
After you run
supportSave
, locate the compact flash usage information in the
supportSave
output
files named
XXX_SUPPORTSHOW
(where
XXX
is
a switch, date, or time prefix). Open the
XXX_SUPPORTSHOW
file in any text editor and search for the following information:
Verify that the compact flash usage is not above 90%. If the compact flash usage is above 90%,
contact HP.
NOTE:
If running Fabric OS 4.2.x or earlier, enter the
supportShow
command and verify the above
compact flash information by searching the output of the
supportShow
command.
7.
(Optional) Enter the
errClear
command to erase all existing messages in addition to internal
messages.
Checking connected switches
When checking connected switches, ensure that any older versions are supported. See the recommended
version (shown in
Table 46
) before upgrading firmware on the switch.
NOTE:
Please go to
http://h18006.www1.hp.com/storage/saninfrastructure/index.html
to view end of
life policies for HP products. End-of-life products are not supported.
If the switch to be upgraded is running version 4.1.x (or later), it is recommended that all switches directly
connected to it be running versions no earlier than 2.6.1, 3.1.x, or 4.1.x. If some connected switches are
running older firmware, upgrade them to
at least
the earliest recommended version (shown in
Table 43
)
before upgrading firmware on your switch.
IMPORTANT:
Refer to the “Current supported Fabric OS versions” table
in the
HP StorageWorks Fabric
OS release notes
for the recommended firmware versions. Access the most up-to-date Release Notes and
the latest supported firmware from
http://www.hp.com
.
es.
1.
Connect to the switch and log in as
admin
.
2.
Enter the
version
command. The following information is displayed:
• Kernel—Displays the version of switch kernel operating system.
• Fabric OS—Displays the version of switch Fabric OS.
• Made on—Displays the build date of firmware running in switch.
• Flash—Displays the install date of firmware stored in nonvolatile memory.
• BootProm—Displays the version of the firmware stored in the boot PROM.
/bin/df:
Filesystem 1k-blocks Used Available Use% Mounted on
/dev/root 120112 61128 58984
51%
/
/dev/hda2 120128 72356 47772
60%
/mnt
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...