Fabric OS 5.3.0 administrator guide 181
To upgrade the firmware on SAN Director 2/128 and 4/256 SAN Director (including the
blades):
1.
Verify that the FTP or SSH server is running on the host server and that you have a user ID on that
server.
2.
Obtain the firmware file from
http://www.hp.com
and store the file on the FTP or SSH server.
3.
Unpack the compressed files preserving directory structures.
4.
The firmware is in the form of RPM packages with names defined in a
.plist
file, that contains
specific firmware information and the names of packages of the firmware to be downloaded.
5.
Connect to the switch and log in as admin.
6.
Use the
firmwareShow
command to check the current firmware version on connected switches.
Upgrade the firmware, if necessary, before proceeding with upgrading this switch.
See
Checking connected switches
, page 176
CAUTION:
4/256 SAN Director with a B-Series MP Router blade
: If you are running 5.1.0x
firmware, you cannot downgrade to earlier versions without removing the blade(s).
4/256 SAN Director with an FC4-48 or FC4-16IP blade:
If you are running 5.2.x firmware, then
you cannot downgrade to earlier versions without removing the blade(s).
Do not remove blades until the EX_Ports, are removed first. The
firmwareDownload
command will
indicate when blades are safe to remove.
7.
Enter the
haShow
command to confirm that the two CP blades are synchronized. In the following
example, the active CP blade is CP0 and the standby CP blade is CP1:
CP blades must be synchronized and running Fabric OS 4.2.x or later to provide a nondisruptive
download. If the two CP blades are not synchronized, enter the
haSyncStart
command to
synchronize them. If the CPs still are not synchronized, contact HP.
8.
Enter the
firmwareDownload
command.
9.
At the “Do you want to continue [y/n]” prompt, type
y
switch:admin>
hashow
Local CP (Slot 5, CP0): Active, Warm Recovered
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
switch:admin>
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...