40
Performing basic configuration tasks
5.
Record the new switch name for future reference.
6.
SAN Director 2/128 configured with two domains
: Disconnect from the session and repeat
the procedure for the second logical switch.
Customizing the chassis name
Beginning with Fabric OS 4.4.x, it is recommended that you customize the chassis name for each switch.
Some system logs identify switches by chassis names, so if you assign meaningful chassis names in
addition to meaningful switch names, logs will be more useful.
How to change the chassis name
1.
Connect to the switch and log in as admin.
2.
Enter the
chassisName
command at the command line, using the following syntax:
where
newname
is the new name for the chassis.
Chassis names can be from 1 to 15 characters long, must begin with a letter, and can contain letters,
numbers, or the underscore character. It is not necessary to use the quotation marks.
3.
Record the new chassis name for future reference.
Working with domain IDs
Although domain IDs are assigned dynamically when a switch is enabled, you can reset them manually so
that you can control the ID number or to resolve a domain ID conflict when you merge fabrics.
If a switch already has a domain ID when it is enabled, and that domain ID conflicts with a switch already
in the fabric, the conflict is automatically resolved. The process can take several seconds, during which time
traffic is delayed.
The default domain ID for HP StorageWorks switches is 1.
The default domain ID applies to the logical switches in the SAN Director 2/128 that are configured for
two domains. To prevent domain conflict, you can either disable one of the switches until the other is
connected to the fabric, then re-enable the switches so that unique domain IDs are automatically assigned,
or you can use the procedure ”
How to set the domain ID
” on page 41 to make the domain IDs unique
before connecting the logical switches to the fabric.
CAUTION:
On switches running Fabric OS v4.x and later, do not use domain ID 0, which is reserved for
another purpose. The use of this domain ID can cause the switch to reboot continuously.
Avoid changing the domain ID on the FCS in secure mode. To minimize down time, change the domain
IDs on the other switches in the secure fabric.
switch:admin>
switchname “switch62”
Committing configuration...
Done.
switch62:admin>
switch:admin>
chassisname
“
newname
”
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...