Fabric OS 5.3.0 administrator guide 203
9
Configuring Directors
This chapter contains procedures that are specific to the SAN Director 128 and 4/256 SAN Director
models. For detailed information about these models, r
efer to the HP StorageWorks SAN Director
installation guide
available on
http://www.hp.com
.
Because Directors contain interchangeable port blades, install procedures differ from the SAN Switches,
which operate as fixed-port switches. For example, fixed-port models identify ports by
domain, port
number
, while Director models identify ports by
slot/port number.
The two available Director models (namely the SAN Director 2/128 and 4/256 SAN Director) in their
default configurations have only one domain (the 4/256 SAN Director supports one domain only).
For more detailed information about the SAN Director 128 and 4/256 SAN Director models, see the
SAN
Director installation guide
.
Identifying ports
The SAN Director 2/128 and 4/256 SAN Director models have slots and can have a variable number of
ports within a given domain. Ports are identified by their combined slot number and port number.
There are 10 slots that contain port blades:
•
Slot numbers 5 and 6 contain
control processor
blades (CPs).
•
Slot numbers 1 through 4 and 7 through 10 contain
port
blades.
NOTE:
CPs perform blade-to-blade switching over the Director’s passive backplane, contain
communication ports for system management, and are used for low-level, chassis-wide tasks.
Port blades are used for host, storage, and interswitch connections.
On each port blade a particular port must be represented by both slot number (1 through 4 and 7 through
10) and port number.
When you have port blades with different port counts in the same Director (for example, 16-port blade and
32-port blades, or 16-port blades and 18-port blades with 16 FC ports and 2 GbE ports, or 16-port and
48-port blades), the area IDs no longer match the port numbers.
Table 51
lists the port numbering schemes
for the 4/256 SAN Director:
Table 51
Port numbering schemes for the 4/256 SAN Director
Port
blades
4/256 SAN Director
FC2-16
FC4-16
Ports are numbered from 0 through 15 from bottom to top.
FC4-32
Ports are numbered from 0 through 15 from bottom to top on the left set of ports
and 16 through 31 from bottom to top on the right set of ports.
FC4-48
Ports are numbered from 0 through 23 from bottom to top on the left set of ports
and 24 through 47 from bottom to top on the right set of ports.
FC10-6
Ports are numbered from 0 through 5 from bottom to top.
FC4-16IP
Fibre Channel ports are numbered from 0 through 7 from bottom to top. There
are also 8 GbE ports (numbered ge0 – ge7, from bottom to top). Going from
bottom to top, the 8 FC ports appear on the bottom, followed by the 8 GbE ports
at the top.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...